Home
Essilor Instruments
Medical Equipment
DELTA
Essilor Instruments DELTA User Manual
4
of 1
of 1 rating
187 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
b.
Legend screen for customized drilling
1.
Type of drilling
◦
Perpendicular to the front surface
◦
Perpendicular to the rear surface
◦
Customized
2.
Select the drilling points
◦
Nasal side
◦
Temporal side
◦
All drilling points
3.
Modify the selected value
4.
Modify the diameter
◦
diameter (mm)
◦
difference between the initial value and the modified value
Delta - Edging System >
V1- 02-2020
118
U
SER
M
ANUAL
> VII. E
DGING
A
LENS
114
116
Table of Contents
Default Chapter
2
Table of Contents
2
Introduction
6
First Teps with Elta
8
Descriptive Diagrams
9
Instructions for Use
10
Turn on the Product
11
Turn off the Product
11
Using the Touch Screen and Keypads
11
Work Screens
14
Carry out an Optical Tracing
17
The Tracing Environment
18
Legend Screen
18
Jobs and Working Modes
20
Shape Management and Storage
21
Legend Screen
22
Job List
24
Creating a Job
24
Working in Current Job Mode (Job A)
25
Optical Tracing
26
Enter the Curve and Frame Base
29
Case of a Mechanical Tracing
31
Connection with a Tess Tracer
31
Connection with a PHI Tracer
34
Center and Block a Lens
35
Centering Environment
36
Description of the Centering Blocking System
36
Legend Screen
40
Calling up a Shape
43
Centering a Single Vision Lens
44
Centering a Progressive Lens
47
Centering a Progressive Lens Using Re-Marked Micro-Engravings
47
Centering a Lens Using Manufacturer Markings
49
Centering Bifocal/Trifocal Lenses
51
Centering an Executive Lens
53
Centering a MID-Distance Lens
55
Centering a Lens Using Re-Marked Micro-Engravings
56
Centering a Lens Using Manufacturer Markings
58
Blocking a Lens
60
Prepare Blocking
60
Blocking
62
Blocking Control and Compensation
65
Modifying the Lens Shape
69
Legend Screen
69
Modifying a Shape
70
Enlarging, Reducing or Rotating a Shape
71
Keep the Perimeter Constant
73
Free-Form Modification
75
Retouching a Shape
76
Archiving/Saving a Shape
77
Preparing a Drilled Job
78
Legend Screen
79
Configuring a Drilling Point
82
Creating a Drilling Point
82
Delete One Drilling Point
83
Dimensioning a Drilling Point
83
Adjusting the Position of a Drilling Point
84
Drilling Models
87
Importing a Model
87
Saving a Model
89
Edging a Lens
90
Edger Working Environment
91
Legend Screen
91
Calling up a Shape
93
Lens Set-Up and Feeling
94
Perform a Beveling
95
Automatic Beveling
95
Legend Screen for Customized Bevels
96
Customized Beveling
98
Modifying the Bevel Curve
99
Modifying the Bevel Curve at a Particular Point
100
Displacing the Bevel Curve
101
Make a Bevel/Tilted Groove
102
Grooving
104
Automatic Grooving
105
Customized Groove Legend Screen
106
Customised Grooving
108
Modifying the Groove Curve
109
Modifying a Point in the Groove Curve
110
Displacement of the Groove Curve
111
Produce a Flat-Edge Finish
112
Perform a Drilled Job
113
Automatic Drilling
114
Legend Screen for Customized Drilling
115
Customized Drilling
116
Perform a Polishing
118
Chamfering
118
Perform a Retouching
120
Set up the Product
122
Configure the Tracer-Centerer-Blocker and the Edger
123
Time, Date and Language
123
Screensaver
124
Connections
125
Customize the Tracer and the Centering Device
126
Working Modes and Display Precision
126
Decentration Mode
128
Action Bar
129
Brightness
131
Centering Compensation
132
Adjusting the Precision of the Edger
133
Adjusting the Diameter of the Finished Lenses
133
Adjusting the Position of the Bevel and Groove
134
Adjusting the Diameter of Drill-Holes
135
Adjusting the Chamfer
136
Adjusting the Groove
137
Set Default Size Settings
138
Restoring the Factory Settings
141
Maintenance and Servicing
142
Perform the Autotest of the Tracer
143
Performing the Edger Autotest
144
Checking and Calibrating the Tracer
145
Calibrate the Touch Screen
145
Control and Calibrate the Centering Device
146
Control and Calibrate the Blocker
148
Check the Optical System
150
Test and Calibrate the Edger
150
Control the Calibration of the Monofeeler
150
Calibrate the Touch Screen
152
Statistics and Technical History of the Tracer
152
Tracer-Centerer-Blocker Statistics
153
Technical History Log and Errors
155
Statistics and Technical History of the Edger
157
Edger Cycles
157
Technical History Log and Errors
158
Making a Backup of the Jobs and Display Configuration
159
Changing or Cleaning the Blocking Tube
161
Change or Clean the Edger Tools
163
Changing or Cleaning the Drill Bit
164
Changing the Grooving or Chamfering Wheel
165
Maintain and Clean the Tracer-Centerer-Blocker
168
Precautions Required
168
Clean the Reflectors and the Lens
168
Clean the Tube
168
Maintaining and Cleaning the Edger
168
Precautions Required
169
Clean the GCD Module
169
Remove and Clean the Window
169
Dress the Wheels
171
Technical Data
173
Environment
174
General Features
174
Tracer Centering Device Blocker" Function
175
Edger" Function
176
General Information
178
4 “Edger” Function
179
Symbols
179
Modifications
180
Declaration of Conformity
180
Copyright
180
Materials and Products
181
Safety Instructions
181
Electromagnetic Waves
182
Glossary
183
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Essilor Instruments DELTA and is the answer not in the manual?
Ask a question
Essilor Instruments DELTA Specifications
General
Brand
Essilor Instruments
Model
DELTA
Category
Medical Equipment
Language
English
Related product manuals
Essilor Instruments Retina 550
31 pages
VISIOSMART 500
32 pages
Essilor Instruments APH 550
78 pages