TRANSCEIVER OPERATIONS
AGC presets:
· OFF - AGC is off.
Set this AGC preset, if you need to switch off the AGC.
Note:
(
If the AGC is OFF, RF knob will adjust the IF gain.
· LONG - Long AGC.
Set the LONG preset to use long AGC reaction (approximately 750 ms). Recommended for
phone modes.
· SLOW - Slow AGC.
Set the SLOW preset to use slow AGC reaction (approximately 500 ms). Recommended for
phone, digital modes.
· MED - Medium AGC.
Set the MED preset to use medium AGC reaction (approximately 250 ms). Recommended
for CW, digital modes.
· FAST - Fast AGC.
Set the FAST preset to use fast AGC reaction (approximately 100 ms). Recommended for
CW, digital modes.
· USER - Custom AGC.
Set the USER preset to use custom AGC reaction (by default the slowest 1000 ms).
Note:
(
AGC settings influence the quality of the received signal. Be careful selecting the AGC preset
or tuning your own preset.