Command and Response Tables (continued)
Command
Function
SIS Command
(Host to Device)
Response
(Device to Host)
Additional Description
Set unit name
E X1@
CN
}
Ipn
X1@
]
Set unit name to
default
E
CN
}
Ipn
X10)
]
View unit name
E
CN
} X1@
]
View Telnet
connections
E
CC
}
n
]
Iccn
]
n=number of active IP
connections. Verbose
mode3 returns Iccn
Set verbose mode
E X2@
CV
}
Vrb
X2@]
View verbose
mode
E
CV
} X2@]
System Commands
Backup/Restore
Save configuration
E
1*
X1)
XF
}
Cfg1*
X1) ] Save configuration to file
location (/nortxe-backup).
Restore
configuration
E
0*
X1)
XF
}
Cfg0*
X1) ] Load configuration from file
location (/nortxe-backup).
Resets
Reboot system
E
1BOOT
}
Boot1
]
Complete system reboot.
Restart the
network
E
2BOOT
}
Boot2
]
Reset flash
E
ZFFF
}
Zpf
]
Reset flash memory
(excludes recording files).
System Reset
(factory defaults)
E
ZXXX
}
Zpx
]
Resets device to default and
deletes recorded files.
Reset all device
settings and delete
recording files
E
ZY
}
Zpy
]
Reset to default except IP
address, delete all user and
recorded files
NOTE: This reset excludes IP settings such as IP address, subnet mask, gateway IP address, unit name, DHCP setting and port
mapping (Telnet/Web/direct access) in order to preserve communication with the device.
Absolute reset
E
ZQQQ
}
Zpq
]
Same as System Reset, plus
returns the IP address and
subnet mask to defaults.
Front panel lock (executive mode)
Set Executive
mode
X5!
X Exe
X5!]
View Executive
mode
X
X5!]
NOTES: X1) = Configuration type 0 = IP config (ip.cfg)
2 = Box specific parameters (box.cfg)
X1@ = Unit name Unit name is a text string of up to 63 characters drawn from the alphabet (A-Z), digits (0-9),
and the minus sign/hyphen (-). The first character must be an alpha character. The last
character must not be a minus.
X2@ = Verbose/Response mode 0=clear/none (default for Telnet connections)
1=verbose mode (default for USB and RS-232 host control)
2=tagged responses for queries
3=verbose mode and tagged responses for queries
NOTE: If tagged responses is enabled, all read commands return
the data, the same as setting the value does
(Example: command:
E
CV} Response: Vrb3
])
X5! = Executive mode 0=Off
1=complete lockout (no front panel control)
2=menu lockout
3=Allow recording controls only
X10) = Default name Combination of model name and last three pairs of MAC address
(Example: SMP-351-07-8C-EC)
165SMP351 • Remote Communication and Control

Table of Contents

Other manuals for Extron electronics SMP 351

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics SMP 351 and is the answer not in the manual?

Extron electronics SMP 351 Specifications

General IconGeneral
BrandExtron electronics
ModelSMP 351
CategoryProcessor
LanguageEnglish

Related product manuals