EasyManuals Logo

Extron electronics SMP 351 User Manual

Extron electronics SMP 351
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
SMP351 Rear Panel Reset
The Reset button on the rear panel of the SMP351 (see figure 3 on page 12) returns
the SMP351 to various modes of operation. To select different reset modes, use a pointed
stylus or small screwdriver to press and hold the Reset button while the SMP351 is
powered or press and hold the Reset button while applying power to the SMP351.
NOTES:
The reset modes listed in the table on the next page close all open IP and Telnet
connections and all sockets.
Each reset mode is a separate reset (not a continuation from mode 1 to mode 5).
Reset modes 2 and 3 are not available for the SMP351.
The SMP351 can also be reset using the Web-based user interface (see System
Resets on page148).
For information on resetting the SMP351 using SIS commands, see Resets on
page165.
Further details comparing the reset modes and detailing affected configuration
settings and user content are available in the operations section below.
ATTENTION:
Review the reset modes carefully. Some reset modes delete all user loaded
content and revert the device to default configuration.
Étudier de près les différents modes de réinitialisation. Certains modes de
réinitialisation suppriment la totalité du contenu chargé de l’utilisateur et remettent
l’appareil en mode de configuration par défaut.
There are three unit reset modes (numbered 1, 4, and 5) that are initiated from the rear
panel reset button. Press the button with a pointed stylus, pen, or similar item to access the
modes. See the following for a summary of the reset modes.
RESET
RESET
RESET RESET
RESET RESET
RESET
RESET
Press and hold
the Reset button.
Mode 1
Apply power
to the SMP 351.
Release Reset button.
Release, then immediately
press and release again.
Reset LED flashes, then goes off.
Mode 4
Reset LED flashes twice.
Press and hold
for 6 seconds.
Release, then immediately
press and release again.
Reset LED flashes, then goes off.
Mode 5
Reset LED flashes three
times.
Press and hold
for 9 seconds.
Figure 6. Resetting the SMP351
SMP351 • Installation 16

Table of Contents

Other manuals for Extron electronics SMP 351

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics SMP 351 and is the answer not in the manual?

Extron electronics SMP 351 Specifications

General IconGeneral
BrandExtron electronics
ModelSMP 351
CategoryProcessor
LanguageEnglish

Related product manuals