Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional
Description
Vertical Centering
Specify a value
E
1*
X50@
*
X61!
VCTR
}
Vctr
X50@
*
X61! ]
Set vertical centering to
X61!
.
Increment value
E
1*
X50@
+ VCTR
}
Vctr
X50@
*
X61! ]
Shift window down.
Decrement value
E
1*
X50@
− VCTR 
}
Vctr
X50@
*
X61! ]
Shift window up.
View
E
1*
X50@
VCTR
}
X61! ]
View current setting.
Vertical size
Specify a value
E
1*
X50@
*
X61#
VSIZ
}
Vsiz
X50@
*
X61# ]
Set vertical size (height) to
X61#
.
Increment value
E
1*
X50@
+ VSIZ
}
Vsiz
X50@
*
X61#]
Increase the height of the
window.
Decrement value
E
1*
X50@
− VSIZ 
}
Vsiz
X50@
*
X61# ]
Decrease the height of the
window.
View
E
1*
X50@
VSIZ
}
X61# ]
View current setting.
Video Mute
Mute output to
black
X50@
* 1B Vmt
X50@
*01
]
Mute channel
X50@
output.
Unmute output
X50@
* 0B Vmt
X50@
* 00
]
Unmute channel
X50@
output.
View video mute
status
X50@
B
X( ]
00=unmuted
01=muted
EDID Minder
Assign EDID to
specific input
E
A
X50!
*
X6*
EDID
}
EdidA
X50!
*
X6*
] X50!
= video inputs 1, 2, and 4
X6*
= See the EDID Values
table on page178)
View EDID
assignment
E
A
X50!
EDID
} X6* ]
Import EDID to
user location
E
I
X6&
,[lename]EDID
}
EdidI
]
Import a 128 or 256-Byte binary
EDID file to the user loaded
EDID location [39 to 41].
Save EDID to user
location
E
S
X50@
*
X6&
EDID
}
EdidS
X50@
*
X6&
]
Save output
X50@
EDID to user
slot
X6&
.
Export EDID in
binary format
E
E
X6*
,[lename]
EDID
}
EdidE
]
Export a 128 or 256-Byte binary
EDID file from EDID location
X6*
.
[filename] can optionally carry a
full path name. The EDID file is
a .bin file, carrying 128 or 256
bytes of binary data.
NOTES:
X(
= On/off 0=disabled/unassigned/off/unmuted
1=enabled/assigned/on/muted
X6&
= EDID User loaded slots 1, 2, and 3
X6*
= EDID number See the EDID Values table on page178)
X50!
= Input number 1 to 5
X50@
= Output channel 1=A
2=B
X61!
= Vertical centering The value corresponds to the vertical position of the top edge of the window. The range
varies such that the window never goes completely off-screen.
X61#
= Vertical size 64 to 4096