UMG70XV3-4EN 12.01.2009 179
A Technical Data
Shear Wave Transducers (for ATEX zone 1, IP 68)
technical type GDK1LI1 GDM2LI1 GDP2LI1 GDG1LI1
order code GSK-NA1TS/
IP68
GSM-NA1TS/
IP68
GSP-NA1TS/
IP68
GSG-NA1TS/
IP68
transducer frequency MHz 0.5 1 2 0.2
medium pressure
1
min. extended bar 20 20 20 20
min. bar metal pipe: 30
plastic pipe: 1
metal pipe: 30
plastic pipe: 1
metal pipe: 30
plastic pipe: 1
metal pipe: 30
plastic pipe: 1
outer pipe diameter
2
min. extended mm 70 30 15 250
min. recommended mm 80 40 20 380
max. recommended mm 500 80 40 810
max. extended mm 720 120 60 1100
pipe wall thickness
min. mm 5 2.5 1.5 14
max. mm - - - -
material
housing PEEK with
stainless steel
cap316Ti
(1.4571)
PEEK with
stainless steel
cap316Ti
(1.4571)
PEEK with
stainless steel
cap316Ti
(1.4571)
PEEK with
stainless steel
cap316Ti
(1.4571)
contact surface PEEK PEEK PEEK PEEK
degree of protection
according to EN 60529
IP 68 IP 68 IP 68 IP 68
transducer cable
type 2550 2550 2550 2550
length m 12 12 12 12
dimensions
length l mm 128.5 70 70 128.5
width b mm50282850
height h mm 72 42 42 75
dimensional drawing
operating temperature
min. °C -40 -40 -40 -40
max. °C +100 +100 +100 +100
continued on next page