UMG70XV3-4EN 12.01.2009 181
A Technical Data
Shear Wave Transducers (for ATEX zone 1/2 (gas/dust), high temperature)
technical type GDM2E85 GDP2E85
order code GSM-EA1TS GSP-EA1TS
transducer frequency MHz 1 2
medium pressure
1
min. extended bar 20 20
min. bar metal pipe: 30
plastic pipe: 1
metal pipe: 30
plastic pipe: 1
outer pipe diameter
2
min. extended mm 30 15
min. recommended mm 40 20
max. recommended mm 80 40
max. extended mm 120 60
pipe wall thickness
min. mm 2.5 1.5
max. mm - -
material
housing PI with stain-
less steel
cap304
(1.4301)
PI with stain-
less steel
cap304
(1.4301)
contact surface PI PI
degree of protection
according to EN 60529
IP 56 IP 56
transducer cable
type 6111 6111
length m 4 4
dimensions
length l mm 69.5 69.5
width b mm 32.5 32.5
height h mm 61 61
dimensional drawing
operating temperature
min. °C -30 -30
max. °C +200 +200
continued on next page