UMG70XV3-4EN 12.01.2009 193
A Technical Data
Lamb Wave Transducers (for ATEX Zone 1)
technical type GRM1N83 GRP1N83 GRQ1N83
order code GLM-NA1TS GLP-NA1TS GLQ-NA1TS
transducer frequency MHz 1 2 4
medium pressure
1
min. extended bar - - -
min. bar metal pipe:
10 (> DN 60)
5 (< DN 60)
metal pipe:
10 (> DN 35)
5 (< DN 35)
metal pipe:
10 (> DN 15)
5 (< DN 15)
outer pipe diameter
2
min. extended mm 30 15 7
min. recommended mm 40 20 10
max. recommended mm 90 50 22
max. extended mm 150 70 35
pipe wall thickness
min. mm 2 1 0.5
max. mm 5 3 1
material
housing PPSU with
stainless steel
cap304
(1.4301)
PPSU withwith
stainless steel
cap304
(1.4301)
PPSU with
stainless steel
cap304
(1.4301)
contact surface PPSU PPSU PPSU
degree of protection
according to EN 60529
IP 65 IP 65 IP 65
transducer cable
type 1699 1699 1699
length m 4 4 3
dimensions
length l mm 74 74 42
width b mm282818
height h mm 42.9 42.9 25.5
dimensional drawing
operating temperature
min. °C -40 -40 -40
max. °C +170 +170 +170