UMG70XV3-4EN 12.01.2009 197
A Technical Data
Lamb Wave Transducers (for ATEX Zone 2 or without Explosion Protection)
technical type GRM1N52 GRP1N52 GRQ1N52
order code GLM-NA2TS
GLM-NNNTS
GLP-NA2TS
GLP-NNNTS
GLQ-NA2TS
GLQ-NNNTS
transducer frequency MHz 1 2 4
medium pressure
1
min. extended bar - - -
min. bar metal pipe:
10 (> DN 60)
5 (< DN 60)
metal pipe:
10 (> DN 35)
5 (< DN 35)
metal pipe:
10 (> DN 15)
5 (< DN 15)
outer pipe diameter
2
min. extended mm 30 15 7
min. recommended mm 40 20 10
max. recommended mm 90 50 22
max. extended mm 150 70 35
pipe wall thickness
min. mm 2 1 0.5
max. mm 5 3 1
material
housing PPSU with
stainless steel
cap304
(1.4301)
PPSU with
stainless steel
cap304
(1.4301)
PPSU with
stainless steel
cap304
(1.4301)
contact surface PPSU PPSU PPSU
degree of protection
according to EN 60529
IP 65 IP 65 IP 65
transducer cable
type 1699 1699 1699
length m 4 4 3
dimensions
length l mm 74 74 42
width b mm282818
height h mm 42.9 42.9 25.5
dimensional drawing
operating temperature
min. °C -40 -40 -40
max. °C +170 +170 +170
continued on next page