FT-111, User Manual Rev. 2.0.0, June 2022 Page 79 of 137
Alibi records displaying sequence on the display:
The alibi record of the selected weighing is displayed in the sequence below.
1. Alibi record number
2. Date
3. Consecutive number
Search with Alibi record number:
1. Press key after selecting NUM in parameter 813.
2. After entering alibi number in the printout data press key. You may navigate in the alibi
memory with or keys after entering alibi number.
3. The weighing data in the alibi memory is indicated on the display.
4. Press key to print this record and the previous nine weighing.
5. Press key 4 times to return operation.
Search with date:
1. Press key after selecting DATE in parameter 813.
2. After entering alibi number in the printout data press key. The date format entry should be
as in the operation. e.g., date entry should be DDMMYY if parameter 251 is set to DMY. You may
navigate in the alibi memory with or keys after entering the date.
3. The weighing data in the alibi memory is indicated on the display.
4. Press key to print this record and the previous nine weighing.
5. Press key 4 times to return operation.
Transfer all Alibi records:
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 2 times and key 3 times to access parameter 814.
3. Press key to select PRNT and press key to start transferring.
4. Or you may stop transferring by pressing key.
About Alibi Memory:
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 2 times and key 4 times to access parameter 815.
3. Press key to print alibi information.
Format Alibi Memory:
Warning: Alibi memory formatting should be done by authorized person. Otherwise erasing alibi memory
may bring you undesired legal responsibility.
Warning: Alibi memory should not be inserted to the PC.
You may need to format alibi memory after installing the used SD card into the instrument to erase previous
This process requires the calibration switch in programming position.
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 2 times and key 5 times to access parameter 816.
3. Select YES and press key.
4. The warning prompt [ ARE YOU SURE? ] appears on the display.
5. Press key to start formatting or press key to escape.
6. Press key 3 times to return operation.
The empty fields are indicated as [ ------- ] and transferred as [ NO RECORD ]; and the corrupted records
are indicated as [ Error ] and transferred as [ CORRUPTED ].