11.4.1 BSI-Base Commands
BSI-BASE Command Table:
Read all weight data
immediately
[ADR][A][STATUS][SIGN][NET W]
[SIGN][TARE W] [SIGN] [GROSS W]
Read Gross weight value
immediately
[ADR][B][STATUS][SIGN][WEIGHT
VALUE]
Read the last printed data
[ single line data format ]
Read stable weight and
Record to Alibi
[ADR][DV][A][STATUS][SIGN][NET W]
[SIGN][TARE W][SIGN] [GROSS W]
[ALIBI NUMBER]
Erase all data loggings on
the SD card.
Start / stop continuous data
output
[ADR][F] [X]
X=0; Disable
X=1; Enable
Read voltage value of DC
power supply
[ADR][G][STATUS][VOLTAGE VALUE]
Read current weight
(indicated) value
immediately
[ADR][I][STATUS][SIGN][WEIGHT
VALUE]
Read all data logging in the
SD card
[ADR][P][STATUS][SIGN][WEIGHT
VALUE]
[ADR][Q][SP No][L][SIGN][SP
VALUE]
[ADR][R][STATUS][SIGN][SP VALUE]
[ADR][S][STATUS-1][STATUS-2]
[STATUS-3]
[ADR][V][STATUS][Outputs]
Command: 01P[CHK][CR][LF]
Response: 01PS+000123.4[CHK][CR][LF]