EasyManua.ls Logo

Flintec FT-111 - BSI-Base Commands

Flintec FT-111
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-111, User Manual Rev. 2.0.0, June 2022 Page 82 of 137
11.4.1 BSI-Base Commands
BSI-BASE Command Table:
Description
Command
Response
Read all weight data
immediately
[ADR][A]
[ADR][A][STATUS][SIGN][NET W]
[SIGN][TARE W] [SIGN] [GROSS W]
Read Gross weight value
immediately
[ADR][B]
[ADR][B][STATUS][SIGN][WEIGHT
VALUE]
Clear the tare memory
[ADR][C]
[ADR][C][A]
Read the last printed data
[ADR][DO]
[ single line data format ]
Print the label
[ADR][DJ]
[ADR][DJ][A]
Read stable weight and
Record to Alibi
[ADR][DV]
[ADR][DV][A][STATUS][SIGN][NET W]
[SIGN][TARE W][SIGN] [GROSS W]
[ALIBI NUMBER]
Erase all data loggings on
the SD card.
[ADR][E]
[ADR][E][A]
Start / stop continuous data
output
[ADR][F] [X]
X=0; Disable
X=1; Enable
[ADR][F][A]
Read voltage value of DC
power supply
[ADR][G]
[ADR][G][STATUS][VOLTAGE VALUE]
Read current weight
(indicated) value
immediately
[ADR][I]
[ADR][I][STATUS][SIGN][WEIGHT
VALUE]
Read all data logging in the
SD card
[ADR][L]
[ADR][L][A][All DATA]
Read the scale name
[ADR][N]
[ADR][N][A][16 digits]
Read the stable weight
[ADR][P]
[ADR][P][STATUS][SIGN][WEIGHT
VALUE]
Load set points
[ADR][Q][SP No][L][SIGN][SP
VALUE]
[ADR][Q][STATUS]
Read set points
[ADR][R][SP No][L]
[ADR][R][STATUS][SIGN][SP VALUE]
Read Status
[ADR][S]
[ADR][S][STATUS-1][STATUS-2]
[STATUS-3]
Tare
[ADR][T]
[ADR][T][STATUS]
Read digital inputs
[ADR][U]
[ADR][U][STATUS][Inputs]
Read digital outputs
[ADR][V]
[ADR][V][STATUS][Outputs]
Command: 01P[CHK][CR][LF]
Checksum
=
0x31 + 0x50)
=
=
0x4F
=
Response: 01PS+000123.4[CHK][CR][LF]
Checksum
=
0x2E + 0x34)
=
=
0x49
=

Table of Contents