EasyManua.ls Logo

Flintec FT-111 - Page 83

Flintec FT-111
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-111, User Manual Rev. 2.0.0, June 2022 Page 83 of 137
Set/Reset digital outputs
[ADR][W][Outputs]
[ADR][W][STATUS]
Read weight value in
increased resolution
[ADR][X]
[ADR][X][STATUS][SIGN][WEIGHT
VALUE]
Zero
[ADR][Z]
[ADR][Z][STATUS]
BSI-Base Commands and Responses:
A
Read all weight data immediately
B
Read Gross weight value immediately
C
Clear the tare
DO
Read the last printed data
DJ
Print the label
DV
Read stable weight and Record to Alibi
E
Erase the logs in the SD card.
F
Start /stop continuous data output
G
Read voltage value of DC power supply
I
Read current weight (indicated) value immediately
L
Read the logs in the SD card.
N
Read the scale name
P
Read the current stable weight value
Q
Load set point values
R
Read set point values
S
Read Status
T
Tare
U
Read digital inputs
V
Read digital outputs
W
Set/Reset digital outputs
X
Read current weight value in increased resolution immediately
Z
Zero
A
Read all weight data
Command : [ADR][A]
Response : [ADR][A][STATUS][SIGN][NET W][SIGN][TARE W][SIGN][GROSS W]
Example :
Command : 01A
Response : 01AS+000123.4+000111.1+000234.5
01AD+000123.4+000111.1+000234.5
01AO (ADC out error )
Comments :
The response is net, tare and gross weight values or error status.
All weight data is transmitted immediately after receiving the command.
B
Read Gross weight
Command : [ADR][B]
Response : [ADR][B][STATUS][SIGN][WEIGHT VALUE]
Example :
Command : 01B
Response : 01BS+000123.4 (gross weight is stable and 123.4)
01BD+000123.4 (gross weight is dynamic and 123.4)
(under load)
Comments :
The response is the gross weight value (stable or dynamic) or error status.
Gross weight data is transmitted immediately after receiving command.

Table of Contents