FT-111, User Manual Rev. 2.0.0, June 2022 Page 6 of 137
2 INTRODUCTION
2.1 OVERVIEW
FT-111 Weighing Terminal is an economical and powerful state-of-the-art measuring instrument. It is ideal for
industrial weighing applications like basic weighing, labelling, system control with digital outputs, fieldbus
interfacing, etc. Its set values memory with 500 items record size which each item has 5 pieces limit values
gives big advantage in operation.
Digital inputs and outputs of the instrument can be programmed as a Remote IO on the fieldbus. This feature
The scales equipped with FT-111 weighing terminal can be used in all kinds of industrial areas up to harsh,
wet, and hygienic environments with its fast and efficient cleaning that was designed and built according to
the international guidelines.
2.2 SPECIFICATIONS
Analogue Load cell
A/D converter type
24 bit Delta-Sigma ratio metric with integral analogue and digital filters
Conversion rate
Up to 800 measurement values per second
Input sensitivity
0,4 μV/e approved, 0.05 μV/e non approved.
Analogue input range
-5 mV to +19 mV
Internal resolution
up to 16 000 000
Excitation
5 VDC max. 125 mA
Number of load cells
Up to 8 load cells 350 Ω or 25 load cells 1100 Ω.
Connection
4- or 6-wire technique.
Home cable length: maximum 1000 m/mm² for 6-wire connection between
FT-111 and junction box.
Scale
Range
Single range, up to 3 x multi-intervals, up to 3 x multi ranges.
Display resolution
Approval, up to 10 000 division at usage in trade, according to EN45501 and
OIML R76. Up to 999 999 division at industrial usage.
Platform
Every kind of platform which is equipped with strain gage-based load cells.
Calibration and Functions
Calibration
Calibration with test weights,
eCal electronic calibration without test weights,
Temporary zero calibration,
Zero adjustment, Gain adjustment,
Coefficient entry.
Digital filter
5 steps programmable adaptive filter
Average filter
Programmable dynamic filter
Weighing functions
Taring, zeroing, auto zero tracking, motion detection, auto zero at power up,
tare status saves at power off, increased resolution, automatic tare and clear,
temporary gross indication, unit change.