11.5 CONTINUOUS DATA FORMATS
RELATED PARAMETERS: Parameters 111, 121, 131 and 141.
Continuous data output can be programmed to some common formats besides Flintec continuous formats.
To select one of the described formats below press the key sequentially. Press key to go to the
next parameter.
Flintec
®
Start of transmission character.
1 = Zeroed
with
power on
zerp
Always 0 as ASCII ( 30 hex ).
These seven characters are a string containing the current weight not
including the decimal point.
These seven characters are a string containing the tare weight not
including the decimal point.
Checksum byte. Checksum calculation is;
CHK (Checksum) = 0 ( STX + STATUS A + ..... + LF )
(1) Error Messages: UNDER, OVER, A.OUT, L-VOLT and TILT are represented in Indicated data fields as
left aligned.