FT-111, User Manual Rev. 2.0.0, June 2022 Page 84 of 137
Command : [ADR][C]
Response : [ADR][C][A] (Cleared and the scale is in gross mode)
Comments:
The response status is always Ack in weighing or force mode.
Read the last printed data
Command : [ADR][DO]
Response : [single line data format]
Example :
Command: 01DO
Response: G: 53.55kg T: 0.00kg N: 53.55kg
Comments:
The last printed values are transmitted immediately after receiving the command.
Single line data format can be change due to its configuration. Refer to section 7.3 and sub-block [16].
Command : [ADR][DJ]
Response : [ADR][DJ][ STATUS]
Example :
Command : 01DJ
Response : 01DJA (Weight is stable and printed) or
01DJN (Could not print)
Comments:
Checks status and it must be stable. Else Nack status is send.
Status can be Stable or Nack.
Read stable weight and Record to Alibi
Command : [ADR][DV]
Response : [ADR][DV][STATUS][SIGN][NET W][SIGN][TARE W][SIGN][GROSS W][ALIBI NUMBER]
Example :
Command : 01DV
Response : 01DVS+000123.4+000111.1+000234.5*00001*
01DVO (ADC out error)
Comments :
The response is net, tare, gross weight and alibi number values or error status.
All weight data is transmitted immediately after receiving the command if weight is stable.
Erase the all data logging in the SD card
Command : [ADR][E]
Response : [ADR][E][ STATUS]
Example :
Command : 01E
Response : 01EA (All data logging erased) or
01EN (Data logging could not erased)
Comments:
Acknowledge (ACK) is transmitted after all data logging erased.
Start /stop continuous data output
Command : [ADR][F][ENABLE/DISABLE]
Response : [ADR][F][STATUS]
Example :
Command : 01F1 (Enable)
01F0 (Disable)
Response : 01FA (Command is done successfully)
01FN (Command could not executed)
Comments: Indicated weight value sends continuously.
Continuous data format is [ADR][I][STATUS][SIGN][WEIGHT VALUE].