FT-111, User Manual Rev. 2.0.0, June 2022 Page 9 of 137
CC-Link (optional)
Data rate
156 kbit/s 10 Mbit/s (selectable)
Topology
Line with Trunkline, Branch structure and Termination at both Ends.
Installation
3 wires shielded twisted pair cable.
Max. Stations
Up to 64 stations per network
Isolation
Galvanically isolated bus electronics
Response speed
Up to 4 ms. response delay after read/write commands
Powerlink (optional)
Compatibility
Supports Ethernet POWERLINK V2.0 Communication Profile Specification
version 1.2.0
Data rate
100 Mbit/s, half duplex
XDD file
XDD-file provided
Ring redundancy
Available
Topology
100% free choice of star, tree, ring or daisy chain
Installation
Switched Ethernet transmission with shielded twisted pair cables and RJ-45
connectors.
Isolation
Galvanically isolated bus electronics
Response speed
Min. 4 ms response delay after read/write commands
Power Consumption
100 240 VAC, 50 60 Hz max. 25 mA + max. 50 mA for fieldbus interfacing
OR 12 28 VDC 250 mA + max. 500 mA for fieldbus interfacing
Environment and Enclosure:
Operation temp. range
Approved scales -10 °C to +40 °C
Industrial usage -15 °C to +55 °C
Humidity
Approved scales 80% RH max, non-condensing
Industrial usage 90% RH max, non-condensing
Enclosure
Stainless steel
Protection
IP67
Sizes ( W x H x D )
Wall type
: 260 x 200 x 64 mm (
Weight
2,3 kg ( 5,07 lb )
Packing sizes
Weight packed
3,2 kg ( 7,05 lb )