Device Functions Proline Promass 83 8 Block INPUTS
8.2.2 Function group OPERATION
INPUTS F
STATUS INPUT FAA
CURRENT INPUT FCA
CONFIGURATION 520
OPERATION 524
Function description
INPUTS o CURRENT INPUT o OPERATION
ACTUAL CURRENT
INPUT
(5240)
The actual value of the input current appears on the display.
Display:
0.0...25 mA
SIMULATION
CURRENT INPUT
(5241)
Use this function to activate simulation of the current output.
Options:
OFF
ON
Factory setting:
OFF
! Note!
An active simulation is indicated by the
“SIM. CURRENT 1” (# 661) notice message.
The value output for the simulation at the current input is defined in the function
VALUE SIMULATION CURRENT INPUT (5242).
The measuring device remains fully operational during the simulation and the current
measured values are output correctly via the other outputs and the display.
" Caution!
The setting is not saved if the power supply fails.
VALUE SIMULATION
CURRENT INPUT
(5242)
! Note!
This function is only available if the function SIMULATION
CURRENT INPUT (5241) is switched on.
Use this function to specify a freely selectable value, e.g. 12 mA, which is to be simulated
at the current input. This value is used to test downstream devices and the measuring
device itself.
User input:
0.00...25.00 mA
Factory setting:
0.00 mA or 4 mA (depending on the setting in function 5201).
" Caution!
The setting is not saved if the power supply fails.