Issue/Rev. 0.2 (12/12) MN0M023 • Page 57
Device Functions Proline Promass 83 6 Block TOTALIZERS
6.1 Group TOTALIZER (1...3)
6.1.1 Function group CONFIGURATION
TOTALIZERS D
TOTALIZER 1 DAA
CONFIGURATION 300
TOTALIZER 2 DAB
CONFIGURATION 300
TOTALIZER 3 DAC
CONFIGURATION 300
Function description
TOTALIZERS o TOTALIZER (1...3) o CONFIGURATION
The function descriptions below apply to totalizers 1...3; the totalizers are independently configurable.
ASSIGN
(3000)
Use this function to assign a measured variable to the totalizer in question.
Options (standard):
OFF
MASS FLOW
VOLUME FLOW
CORRECTED VOLUME FLOW
Advanced options with optional software package CONCENTRATION:
TARGET MASS
TARGET VOLUME
TARGET CORRECTED VOLUME
CARRIER MASS
CARRIER VOLUME
CARRIER CORRECTED VOLUME
Factory setting:
MASS FLOW
! Note!
The totalizer is reset to “0” as soon as the selection is changed.
If you select OFF in the function group CONFIGURATION of the totalizer in question,
only the ASSIGN (3000) function remains visible.