Issue/Rev. 0.2 (12/12)
Page 152 • MN0M023
10 Block SPECIAL FUNCTION Device Functions Proline Promass 83
BATCH STAGES
(7208)
Use this function to define the number of batching stages. Batching can be carried out in
several stages, e.g. 2-stage batching with fast and precise batching.
Options:
1-stage (1 valve or 1-stage batching)
2-stage (2 valves or 2-stage batching)
Factory setting:
1-stage (1 valve or 1-stage batching)
! Note!
• The batching stage selection (number of valves) is directly dependent on the
configuration of the outputs. For 2-stage batching two relay outputs must be available
in the measuring device.
• The functions available in the function group VALVE PARAMETER (page 153) are
dependent on the number of batching stages (number of valves) selected in this
function.
INPUT FORMAT
(7209)
Use this function to define the entry format of the quantities for the switch points of the
valves.
Options:
VALUE-INPUT (e.g. 10 [unit])
%-INPUT (e.g. 80 [%])
Factory setting:
VALUE-INPUT
! Note!
The entry format selected in this function is also used in the function groups VALVE
PARAMETER (page 153) and SUPERVISION (page 158).
Function description
SPECIAL FUNCTION o BATCHING FUNCTION o CONFIGURATION