6 Block TOTALIZERS Device Functions Proline Promass 83
6.2 Group HANDLING TOTALIZER
TOTALIZERS D
TOTALIZER 1 DAA
TOTALIZER 2 DAB
TOTALIZER 3 DAC
HANDLING TOTALIZER DJA
Handling totalizer functions
Function description
TOTALIZERS o HANDLING TOTALIZER o Handling totalizer functions
RESET ALL TOTALIZERS
(3800)
Use this function to reset the totals (including all overflows) of the totalizers (1...3) to
“zero” (= RESET).
Options:
NO
YES
Factory setting:
NO
! Note!
If the device has a status input and if it is appropriately configured, a reset for the totalizer
(1...3) can also be triggered by a pulse (see the ASSIGN STATUS INPUT function (5000)
on page 112).
FAILSAFE ALL
TOTALIZERS
(3801)
Use this function to define the common response of all totalizers (1...3) in case of error.
Options:
STOP
The totalizer is paused until the fault is rectified.
ACTUAL VALUE
The totalizer continues to count based on the current flow measuring value. The fault is
ignored .
HOLD VALUE
The totalizer continues to count the flow that based on the last valid flow value (before
the fault occurred).
Factory setting:
STOP