Issue/Rev. 0.2 (12/12)
Page 14 • MN0M023
3 Block MEASURED VARIABLES Device Functions Proline Promass 83
CORRECTED TARGET
VOLUME FLOW
(0024)
! Note!
This function is not available unless % MASS / % VOLUME was selected in the DENSITY
FUNCTION function (7000), (see page 141).
Use this function to display the currently measured corrected volume flow of the target
fluid. Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
CARRIER MASS FLOW
(0025)
! Note!
This function is not available unless one of the following was selected:
• in the function DENSITY FUNCTION (7000), see page 141:
– % MASS / % VOLUME
– FLEXIBLE and in the function MODE (7010), see page 144, the selection
% MASS 2D or % MASS 3D
Use this function to display the currently measured mass flow of the carrier fluid.
Carrier fluid = transporting liquid (e.g. water).
Display:
5-digit floating-point number, including unit and sign
% CARRIER MASS FLOW
(0026)
! Note!
This function is not available unless one of the following was selected:
• in the function DENSITY FUNCTION (7000), see page 141:
– % MASS / % VOLUME
– FLEXIBLE and in the function MODE (7010), see page 144, the selection
% MASS 2D or % MASS 3D
Use this function to display the currently measured mass flow of the carrier fluid as a %
(of the overall mass flow). Carrier fluid = transporting liquid (e.g. water).
Display:
5-digit floating-point number, including unit and sign
CARRIER VOLUME
FLOW
(0027)
! Note!
This function is not available unless one of the following was selected:
• in the function DENSITY FUNCTION (7000), see page 141:
– % MASS / % VOLUME
– FLEXIBLE and in the function MODE (7010), see page 144, the selection
% VOLUME 2D or % VOLUME 3D
Use this function to display the currently measured volume flow of the carrier fluid.
Carrier fluid = transporting liquid (e.g. water).
Display:
5-digit floating-point number, including unit and sign