EasyManua.ls Logo

FMC Technologies Proline Promass 83 E - Function Description

FMC Technologies Proline Promass 83 E
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue/Rev. 0.2 (12/12)
Page 58MN0M023
6 Block TOTALIZERS Device Functions Proline Promass 83
UNIT TOTALIZER
(3001)
Use this function to define the unit for the totalizer's measured variable, as selected
beforehand.
Options (for the MASS FLOW assignment):
Metric o g; kg; t
US o oz; lb; ton
Arbitrary unit o _ _ _ _
Factory setting:
kg
Options (for the VOLUME FLOW assignment):
Metric o cm
3
; dm
3
; m
3
; ml; l; hl; Ml Mega
US o cc; af; ft
3
; oz f; gal; Kgal; Mgal; bbl (normal fluids); bbl (beer);
bbl (petrochemicals); bbl (filling tanks)
Imperial o gal; Mgal; bbl (beer); bbl (petrochemicals)
Arbitrary unit o _ _ _ _
Factory setting:
m
3
Options (for the CORRECTED VOLUME FLOW assignment):
Metric o Nl; Nm
3
US o Sm
3
; Scf
Factory setting:
Nm
3
TOTALIZER MODE
(3002)
Use this function to define how the flow components are to be totalized.
Options:
BALANCE
Positive and negative flow components. The positive and negative flow components are
balanced. In other words, net flow in the flow direction is registered.
FORWARD (only positive flow components)
REVERSE (only negative flow components)
Factory setting:
Totalizer 1 = BALANCE
Totalizer 2 = FORWARD
Totalizer 3 = REVERSE
RESET TOTALIZER
(3003)
Use this function to reset the sum and the overflow of the totalizer to zero.
Options:
NO
YES
Factory setting:
NO
! Note!
If the device is equipped with a status input, with the appropriate configuration a reset for
each individual totalizer can also be triggered by a pulse (see the function ASSIGN
STATUS INPUT (5000) on page 112).
Function description
TOTALIZERS o TOTALIZER (1...3) o CONFIGURATION

Table of Contents

Related product manuals