EasyManua.ls Logo

FMC Technologies Proline Promass 83 E - Function Group ADDITIONAL VALUES

FMC Technologies Proline Promass 83 E
206 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue/Rev. 0.2 (12/12) MN0M023 • Page 13
Device Functions Proline Promass 83 3 Block MEASURED VARIABLES
3.1.2 Function group ADDITIONAL VALUES
MEASURED
VARIABLES
A
MEASURING VALUES AAA
MAIN VALUES 000
ADDITIONAL VALUES 002
Function description
MEASURED VARIABLES o MEASURING VALUES o ADDITIONAL VALUES
TARGET MASS FLOW
(0020)
! Note!
This function is not available unless one of the following was selected:
in the function DENSITY FUNCTION (7000), see page 141:
% MASS / % VOLUME
FLEXIBLE and in the function MODE (7010), see page 144, the selection
% MASS 2D or % MASS 3D
Use this function to display the currently measured mass flow of the target fluid. Target
fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
% TARGET MASS FLOW
(0021)
! Note!
This function is not available unless one of the following was selected:
in the function DENSITY FUNCTION (7000), see page 141:
% MASS / % VOLUME
FLEXIBLE and in the function MODE (7010), see page 144, the selection
% MASS 2D or % MASS 3D
In this function, the currently measured mass flow of the target fluid is displayed as a %
(of the overall mass flow). Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
TARGET VOLUME FLOW
(0022)
! Note!
This function is not available unless one of the following was selected:
in the function DENSITY FUNCTION (7000), see page 141:
% MASS / % VOLUME
FLEXIBLE and in the function MODE (7010), see page 144, the selection
% VOLUME 2D or % VOLUME 3D
In this function, the currently measured volume flow of the target fluid is displayed.
Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
% TARGET VOLUME
FLOW
(0023)
! Note!
This function is not available unless one of the following was selected:
in the function DENSITY FUNCTION (7000), see page 141:
% MASS / % VOLUME
FLEXIBLE and in the function MODE (7010), see page 144, the selection
% VOLUME 2D or % VOLUME 3D
Use this function to display the currently measured volume flow of the target fluid as a %
(of the overall volume flow). Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign

Table of Contents