Issue/Rev. 0.2 (12/12) MN0M023 • Page 47
Device Functions Proline Promass 83 5 Block USER INTERFACE
5.3.2 Function group MULTIPLEX
USER INTERFACE C
CONTROL CAA
MAIN LINE CCA
ADDITIONAL LINE CEA
CONFIGURATION 240
MULTIPLEX 242
Function description
USER INTERFACE o ADDITIONAL LINE o MULTIPLEX
ASSIGN
(2420)
Use this function to define the second reading to be displayed in the additional line
alternately (every 10 seconds) with the value defined in the function ASSIGN (2400).
Options (standard):
OFF
MASS FLOW
MASS FLOW IN %
VOLUME FLOW
VOLUME FLOW IN %
CORRECTED VOLUME FLOW
CORRECTED VOLUME FLOW IN %
DENSITY
REFERENCE DENSITY
TEMPERATURE
MASS FLOW BARGRAPH IN %
VOLUME FLOW BARGRAPH IN %
CORRECTED VOLUME FLOW BARGRAPH IN %
ACTUAL CURRENT (1...3)
ACTUAL FREQUENCY (1...2)
TOTALIZER (1...3)
TAG NAME
ACTUAL CURRENT INPUT
Factory setting:
OFF
Advanced options with optional software package BATCHING:
BATCH NAME (“BATCH # 1” or “BEER 330”, etc.)
BATCH QUANTITY (overall quantity to be batched)
BATCH COUNTER (batching processes carried out)
BATCH SUM (effective total batching quantity)
BATCH UPWARDS (batching progress upwards)
BATCH DOWNWARDS (batching progress downwards)
! Note!
The options given in the BATCHING software package always refer to the batching
selected (“BATCH # 1”, “BATCH # 2”, etc.) in the BATCH SELECTOR function
(page 147). Example: If BATCH # 1 was selected in the BATCH SELECTOR function
(7200), then only the values from BATCH # 1 (batch name, batch quantity etc.) can be
displayed.
(continued on next page)