Issue/Rev. 0.2 (12/12)
Page 28MN0M023
4 Block QUICK SETUP Device Functions Proline Promass 83
!
Note!
The display returns to the cell QUICK SETUP COMMISSIONING (1002) if you press the X key
combination during parameter interrogation. The stored parameters remain valid.
The “Commissioning” Quick Setup must be carried out before one of the Quick Setups
explained below is run.
m Selecting “DELIVERY SETTINGS” returns each selected unit to the factory setting.
Selecting “ACTUAL SETTING” applies the units you have set previously.
n Only units not yet configured in the current Setup are offered for selection in each cycle. The unit for mass,
volume and corrected volume is derived from the corresponding flow unit.
o The “YES” option remains visible until all the units have been configured. “NO” is the only option displayed
when no further units are available.
p Only the outputs not yet configured in the current Setup are offered for selection in each cycle.
q The “YES” option remains visible until all the outputs have been configured. “NO” is the only option displayed
when no further outputs are available.
r The “automatic parameterization of the display” option contains the following basic settings/factory settings:
YES: Main line = Mass flow; Additional line = Totalizer 1; Information line = Operating/system conditions
No: The existing (selected) settings remain.
s The QUICK SETUP BATCHING is only available when the optional software package BATCHING is installed.