Issue/Rev. 0.2 (12/12)
Page 30MN0M023
4 Block QUICK SETUP Device Functions Proline Promass 83
!
Note!
The display returns to the cell QUICK SETUP PULSATING FLOW (1003) if you press the
X key combination during parameter interrogation.
You can call up this Setup menu either directly from the “COMMISSIONING” Setup menu or
manually by means of the function QUICK SETUP PULSATING FLOW (1003).
Settings for the Pulsating Flow Setup menu:
Fct. code Function name Suggested settings Description
Call up through the function matrix:
B QUICK SETUP QUICK SETUP PULSATING FLOW see p. 25
1003 QUICK SETUP PULS.FLOW YES see p. 25
Basic configuration:
2002 DISPLAY DAMPING 1 second see p. 36
3002 TOTALIZER MODE (DAA) BALANCE see p. 58
3002 TOTALIZER MODE (DAB) BALANCE see p. 58
3002 TOTALIZER MODE (DAC) BALANCE see p. 58
Select the signal type: CURRENT OUTPUT (1...n)
4004 MEASURING MODE PULSATING FLOW see p. 68
4005 TIME CONSTANT 1 second see p. 70
Select the signal type: FREQ./PULSE OUTPUT (1...2) / operating mode: FREQUENCY
4206 MEASURING MODE PULSATING FLOW see p. 79
4208 TIME CONSTANT 0 seconds see p. 84
Select the signal type: FREQ./PULSE OUTPUT (1...2) / operating mode: PULSE
4225 MEASURING MODE PULSATING FLOW see p. 87
Other settings:
8005 ALARM DELAY 0 seconds see p. 181
6400 ASSIGN LF CUT OFF MASS FLOW see p. 122
6402 ON-VALUE LOW FLOW CUT
OFF
Depends on diameter (DN [mm]):
DN 1 = 0.02 [kg/h] or [l/h]
DN 2 = 0.10 [kg/h] or [l/h]
DN 4 = 0.45 [kg/h] or [l/h]
DN 8 = 2.0 [kg/h] or [l/h]
DN 15 = 6.5 [kg/h] or [l/h]
DN 15* = 18 [kg/h] or [l/h]
DN 25 = 18 [kg/h] or [l/h]
DN 25* = 45 [kg/h] or [l/h]
DN 40 = 45 [kg/h] or [l/h]
DN 40* = 70 [kg/h] or [l/h]
DN 50 = 70 [kg/h] or [l/h]
DN 50* = 180 [kg/h] or [l/h]
DN 80 = 180 [kg/h] or [l/h]
DN 100 = 350 [kg/h] or [l/h]
DN 150 = 650 [kg/h] or [l/h]
DN 250 = 1800 [kg/h] or [l/h]
*DN 15, 25, 40 “FB” = Full bore
versions Promass I
see p. 122
6403 OFF-VALUE LOW FLOW CUT
OFF
50% see p. 122
6404 PRESSURE SHOCK
SUPPRESSION
0 s see p. 123