Move the mains switch to the "I" position
IMPORTANT! For optimum welding results, the manufacturer recommends per-
forming an R/L alignment when starting the device for the first time and when
any changes are made to the welding system.
STICK
2
2
Press the "Welding process" button until the LED for the STICK/TIG welding
process lights up and "STICK" is shown on the display.
After a short time, the currently set welding current and the currently set dy-
namic are shown on the display. The welding current and dynamic indicators light
up.
The welding voltage is applied to the welding socket with a three second time lag.
175 20
43
NOTE!
Parameters that have been set on a system component control panel (e.g. wire
feed unit or remote control) might not be able to be changed on the power
source control panel.
3
To change the welding current, turn the left adjusting dial
4
If required, turn the right adjusting dial to change the dynamic
The amended values are applied immediately.
5
Adjust the process parameters accordingly to make user- or application-spe-
cific settings on the welding system
6
Start welding