parameters are changed during synergic welding, the remaining welding paramet-
ers are immediately altered accordingly.
Set the shielding
gas flow rate
1
Open the gas cylinder valve
2
Press the gas-test button
Gas flows out.
The "Gas purging" dialogue window appears on the display, indicating the re-
maining gas purging time. If there is a gas regulator or gas sensor in the weld-
ing system, the actual gas value is also displayed.
3
Turn the adjusting screw on the underside of the pressure regulator until the
pressure gauge shows the required shielding gas flow rate
4
Press the gas-test button
The flow of gas stops.
MIG/MAG or
CMT welding
CAUTION!
Risk of injury and damage from electric shock and from the wire electrode
emerging from the torch.
When pressing the torch trigger:
keep the torch away from your face and body
do not point the welding torch at people
make sure that the wire electrode does not touch any electrically conducting
or earthed (grounded) parts, such as the housing, etc.
1
Press the torch trigger and start welding
Whenever welding ends, the actual values for the welding current, welding
voltage and wire speed are stored, and HOLD appears on the display.
NOTE!
It is not always possible to change parameters that have been set on a system
component control panel (e.g. remote control) on the power source control pan-
el.