Process para-
meters for spot
welding
SPt
Spot welding time
0.1 - 10.0 s
Factory setting: 1.0 s
Process para-
meters for stitch
welding
Int
Interval
off / on
Factory setting: off
Int-t
Stitch welding time
0.1 - 10.0 s
Factory setting: 1.0 s
Int-b
Interval break time
off / 0.1 - 10 s
Factory setting: 1.0 s
Int-C
Interval cycles
constant / ...
Factory setting: constant
Process para-
meters for mon-
itoring and com-
ponents
The following process parameters can be set and displayed for the system com-
ponents of a welding system:
C-C
Cooling unit mode
To determine whether a cooling unit is to be switched on or off, or operated auto-
matically
Setting range: eco / auto / on / off (depending on the cooling unit)
Factory setting: auto
C-t
Delay time flow sensorFor setting the time from when the flow sensor responds
until a warning message is output
Setting range: 5 - 25 s
Factory setting: 10 s
CFU
Cooler flow warning limit
Setting range: off / 0.75 - 0.95 l/min
Factory setting: off