Wire speed 1 - 25 m/min
40 - 980 ipm
Wire drive 4-roller drive
Wire diameter 0.8 - 1.6 mm
0.03 - 0.06 in.
Wirespool diameter max. 300 mm
max. 11.8 in.
Wirespool weight max. 19.0 kg
max. 41.9 lb.
Idle state power consumption at 400
V
31 W
Power source efficiency
at 270 A / 30.8 V
90%
The wirefeeder for the TPS 270i C is integrated in the power source.
1) Interface to a 230/400 V and 50 Hz public grid
TPS 270i
C /MV/nc
Mains voltage (U
1
) 3 x 200 / 230 / 380 / 400 / 460 V
Max. effective primary current (I
1eff
)
3 x 200 V
3 x 230 V
3 x 380 V
3 x 400 V
3 x 460 V
16.9 A
15.1 A
9.5 A
9.7 A
8.5 A
Max. primary current (I
1max
)
3 x 200 V
3 x 230 V
3 x 380 V
3 x 400 V
3 x 460 V
26.5 A
23.7 A
16.0 A
15.3 A
13.4 A
Mains fuse protection
3 x 200 / 230 V
3 x 380 / 400 / 460 V
35 A slow-blow
16 A slow-blow
Mains voltage tolerance -10 / +15%
Grid frequency 50/60 Hz
Cos phi (1) 0.99
Max. permitted mains impedance Z
max
at PCC
1)
117 mOhm
Recommended residual current circuit
breaker
Type B
Welding current range (I
2
)
MIG / MAG
TIG
Rod electrode
3 - 270 A
3 - 270 A
10 - 270 A
Welding current
at 10 min/40 °C (104 °F)
40% / 270 A
60% / 220 A
100% / 190 A
167