EasyManua.ls Logo

Fronius TPS/i COMPACT - Troubleshooting

Fronius TPS/i COMPACT
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
General The power sources are equipped with an intelligent safety system, meaning it has
been possible to dispense with nearly all fuses. After a possible malfunction has
been remedied, the power source can be used again as normal.
Possible malfunctions, warning notices or status codes are shown on the display
as plain text dialogues.
Safety
WARNING!
Danger from electrical current.
This can result in serious personal injury and damage to property.
Before starting work, switch off all devices and components involved, and
disconnect them from the grid.
Secure all devices and components involved so they cannot be switched back
on.
After opening the device, use a suitable measuring instrument to check that
electrically charged components (such as capacitors) have been discharged.
WARNING!
Danger due to insufficient ground conductor connection.
This can result in serious personal injury and damage to property.
The housing screws provide a suitable ground conductor connection for
grounding the housing.
The housing screws must not under any circumstances be replaced by other
screws without a reliable ground conductor connection.
Power source -
troubleshooting
Power source does not function
Mains switch is on, but indicators are not lit up
There is a break in the mains lead; the mains plug is not plugged in
Check the mains lead, ensure that the mains plug is plugged in
Mains socket or mains plug faulty
Replace faulty parts
Mains fuse protection
Change the mains fuse
Short circuit on the 24 V supply of SpeedNet connection socket or
external sensor
Unplug connected components
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy: