Care, maintenance and disposal
General Under normal operating conditions, the power source requires only a minimum of
care and maintenance. However, it is vital to observe some important points to
ensure the welding system remains in a usable condition for many years.
Safety
WARNING!
Danger from electrical current.
This can result in serious personal injury and damage to property.
Before starting work, switch off all devices and components involved, and
disconnect them from the grid.
Secure all devices and components involved so they cannot be switched back
on.
After opening the device, use a suitable measuring instrument to check that
electrically charged components (such as capacitors) have been discharged.
At every start-
up
-
Check mains plug, mains cable, welding torch, interconnecting hosepack and
grounding (earthing) connection for damage
-
Check whether the all-round clearance of 0.5 m (1 ft. 8 in.) is kept to ensure
that the cooling air can easily flow and escape.
NOTE!
Air inlets and outlets must never be covered, not even partially.
If necessary If a lot of dust has accumulated:
-
Remove the fin element on the rear of the housing
-
Detach the air filter located behind and clean
Every 2 months
-
If present: clean air filter
Every 6 months
CAUTION!
Danger due to the effect of compressed air.
This can result in damage to property.
Do not clean electronic components with compressed air from a short dis-
tance.
-
Open the device
-
Blow out the inside of the device with dry and reduced compressed air
-
Also clean the cooling air ducts if there is a large accumulation of dust