Scan Mode Settings
357
Setups
10
Scan Service
Set whether or not to use the scanner feature.
Memory Full Procedure
While scanning an original, if there is insufficient hard disk space for the scanner, a
screen appears, asking how the partly stored data should be handled.
Once a certain time has elapsed with the confirmation screen displayed, the
subsequent processing is determined by these settings.
Cancel Job
The stored data is discarded.
Run Job
The read-in data is treated as valid, and the part of the original read in is treated as a
complete file.
Maximum Stored Pages
Set the maximum number of stored pages of a scan original. You can set a number
from 1 to 999 pages.
Saturation
Set the saturation when scanning a full color original. When carrying out a scan, it is
automatically adjusted according to this setting value.
Note • This feature is only supported by DocuCentre 9000 with Scanner.
Background Suppression Level
For a color scan, set the background suppression level. This is valid when [Background
Suppression] is set to [Auto Suppression].
The larger the value, the stronger the effect of removing background noise.
Note • This feature is only supported by DocuCentre 9000 with Scanner.
Shadow Suppression Level
Set the show-through prevention level. This is valid when [Shadow Suppression] is set
to [On].
Note • This feature is only supported by DocuCentre 9000 with Scanner.
Color Space
Set whether to display the color space feature.
When set to [Enabled], the [Color Space] button appears in the [Image Quality] screen
for a scan job.
Important • When [No] is selected as default and "Color Space" (P.353) is set to [Device Color Space],
[Auto] of [Output Color] in the [General Settings] screen does not appear.
For detailed information on [Color Space], refer to "Scan Options" (P.156).
Note • This feature is only supported by DocuCentre 9000 with Scanner.
2 Sided Original Scan Options
When placing the 2 sided document in the Document Feeder, you can set the scanning
method. You can select from [2 Sided Simultaneous Scan] or [1 Sided Scan].