U41117-J-Z125-7-76 499
Explanation of console messages Message lines
SXSM010 sma#: Memory Module <Id> disabled
ALERT
SXSM010 sma#: Memory Module disabled; Module# = <Id>
ALERT
Meaning
Memory module <Id> is in the “disabled” state. This can be caused by the following:
a) The memory module was disabled in the BIOS setup.
b) The memory module was enabled in the BIOS setup, but has been disabled because
of too many memory errors.
Response
Notify maintenance staff.
SXSM011 sma#: Correctable Memory Error occurred; Module# = <Id>
ALERT
Meaning
A correctable memory error has occurred in memory module <Id>.
Response
Notify maintenance staff.
SXSM012 sma#: Uncorrectable Memory Error occurred; Module# = <Id>
ALERT
Meaning
An uncorrectable memory error has occurred in memory module <Id>.
Response
Notify maintenance staff.
SXSM016 sma#: Fan <Id>: Fan failed
ALERT
Meaning
Non-redundant fan <Id> has failed and must be replaced.
If the fan is inoperable for more than 3 minutes, the SINIX system is shut down and the
server deactivated to prevent the server from overheating.
Response
Notify maintenance staff.
SXSM017 sma#: Fan <Id>: Redundant fan failed
ALERT
Meaning
Redundant fan <Id> has failed. As this fan is redundant, the SINIX system is not shut down.
Response
Notify maintenance staff.