488 U41117-J-Z125-7-76
Message lines Explanation of console messages
SXRD104 WARNING: raid 0:1:0 - Disk: Write-Only, 17300 MB
Meaning
A rebuild is active for the physical disk of controller 0, channel 1, target ID 0.
9.2.15.2 FibreCAT S80 messages
SXRD00<n> s80d: RAID: <weight>: <raid-id> Raid<raid#> enclosure <shelf#> <component>
<status>
Meaning
If there is a status change in a S80 component, a message will be output on the console.
The terms used here have the following meanings:
n 1 - 8
weight Error severity: NOTICE information n=8,9
WARNING soft error n=6,7
ERROR error n=4,5
ALERT critical error n=2,3
raid-id FibreCAT identification (target# of the 2 RAID controllers)
raid# Number of the RAID system (1 – 8)
shelf# Number of the shelf (1 – 7)
component Internal component of the shelf
Disk drive (1 – 14)
Power supply (1 – 2)
Cooling fan (1 – 4)
Enclosure services module (1 – 2)
Loop monitor
Voltage sensor (1 – 6)
Current sensor (1 – 6)
Temperature sensor (1 – 4)
status Status of the component
OK Error corrected
Warning Non-critical error (sensor only)
Critical Critical error
Not Installed Component removed or faulty
Not Available Component not in operation
Unknown Status not available (sensor only)