Page #487 background imageLoading...
Page #487 background image
U41117-J-Z125-7-76 487
Explanation of console messages Message lines
SXRD001 ALERT: raidd: c50d0 - state is Critical
Meaning
This message is only generated when the raidd is started at system boot. The logical disk
0 on controller 0 no longer provides any redundancy. This indicates a hardware problem
with a physical disk belonging to the addressed logical disk.
Response
Notify maintenance staff.
SXRD001 ALERT: raidd: c50d0 - state is Offline
Meaning
This message is only generated when the raidd is started at system boot. A further physical
disk belonging to the logical disk 0 on controller 0 has failed. The addressed logical disk is
no longer accessible.
Response
Notify maintenance staff.
SXRD100 ALERT: c50d0 RAID-1, Critical, 17300 MB, Write Back
Meaning
Logical disk 0 of controller 0 has no error redundancy.
Response
Notify maintenance staff.
SXRD101 ALERT: c50d0 RAID-1, Offline, 17300 MB, Write Back
Meaning
Logical disk 0 of controller 0 is not operable.
Response
Notify maintenance staff.
SXRD102 ALERT: raid 0:1:0 - Disk: Dead, 17300 MB
Meaning
The physical disk of controller 0, channel 1, target ID 0 has failed. All the associated logical
disks are without redundancy.
Response
Notify maintenance staff.
SXRD103 NOTICE: raid 0:1:0 - Disk: Standby, 17300 MB
Meaning
The physical disk of controller 0, channel 1, target ID 0 is not active.

Table of Contents