U41117-J-Z125-7-76 449
Explanation of console messages Message lines
SXCH009 ESCON-adaptor <board> (ser_no <serial-nr) Compare Error in Channel <chn>
ALERT
Meaning
A test of the internal data paths on the ESCON board (PCEAS/PCEAT) which runs during
the startup phase and idle times returned an error.
Response
Replace the ESCON board.
SXCH010 ESCON-adaptor <board> CRC READ Error in Channel <chn>
ALERT
Meaning
During a read access the data was corrupted when it was transferred from the SINIX me-
mory to the ESCON channel.
Response
Replace the ESCON board.
SXCH011 ESCON-adaptor <board> CRC WRITE Error in Channel <chn>
ALERT
Meaning
During a write access the data was corrupted when it was transferred from the ESCON
channel to the SINIX memory.
Response
Replace the ESCON board.
9.2.3 SXCM... (CHIM)
SXCM001 chim1 (sadm9): SCSI-Bus reset
None
This message is part of a message complex (see the section “Bus Reset for SCSI
Controller” on page 542).