U41117-J-Z125-7-76 485
Explanation of console messages Message lines
9.2.15 SXRD... (FibreCAT: RAID)
The table below shows the message numbers with the RAID systems which issue the
messages:
9.2.15.1 Messages of the monitoring daemon for the internal RAID
Messages during ongoing operation
SXRD001 NOTICE: raidd: 0:BBU - charging [xx] completed
SXRD001 NOTICE: raidd: 0:BBU - charging [xx] in progress
Meaning
These messages are normal when the BBU on controller 0 is in operation.
SXRD001 ALERT: raidd: 0:BBU - charging [xx] failed
SXRD001 ALERT: raidd: 0:BBU - pack not present
SXRD001 ALERT: raidd: 0:BBU - module not present
SXRD001 ALERT: raidd: 0:BBU - high temp
SXRD001 ALERT: raidd: 0:BBU - low voltage
SXRD001 ALERT: raidd: 0:BBU - cycles exceeded
Meaning
These messages indicate a hardware problem with the BBU on controller 0.
Response
Notify maintenance staff.
SXRD001 ALERT: raidd: 0:0:1 - disk state changed (Online -> Dead)
Meaning
The physical disk of controller 0, channel 0, target ID 1 has failed. All the associated logical
disks are without redundancy.
Response
Notify maintenance staff.
Message number RAID system Page
SXRD001
SXRD100 - SXRD104
internal RAID 485
SXRD002 - SXRD009 S80 488
SXRD010 CX500, CX3-20 489
SXRD501, SXRD901 CX500, CX3-20 490

Table of Contents