EasyManuals Logo

Fujitsu Siemens Computers pmn User Manual

Fujitsu Siemens Computers pmn
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #485 background imageLoading...
Page #485 background image
U41117-J-Z125-7-76 485
Explanation of console messages Message lines
9.2.15 SXRD... (FibreCAT: RAID)
The table below shows the message numbers with the RAID systems which issue the
messages:
9.2.15.1 Messages of the monitoring daemon for the internal RAID
Messages during ongoing operation
SXRD001 NOTICE: raidd: 0:BBU - charging [xx] completed
SXRD001 NOTICE: raidd: 0:BBU - charging [xx] in progress
Meaning
These messages are normal when the BBU on controller 0 is in operation.
SXRD001 ALERT: raidd: 0:BBU - charging [xx] failed
SXRD001 ALERT: raidd: 0:BBU - pack not present
SXRD001 ALERT: raidd: 0:BBU - module not present
SXRD001 ALERT: raidd: 0:BBU - high temp
SXRD001 ALERT: raidd: 0:BBU - low voltage
SXRD001 ALERT: raidd: 0:BBU - cycles exceeded
Meaning
These messages indicate a hardware problem with the BBU on controller 0.
Response
Notify maintenance staff.
SXRD001 ALERT: raidd: 0:0:1 - disk state changed (Online -> Dead)
Meaning
The physical disk of controller 0, channel 0, target ID 1 has failed. All the associated logical
disks are without redundancy.
Response
Notify maintenance staff.
Message number RAID system Page
SXRD001
SXRD100 - SXRD104
internal RAID 485
SXRD002 - SXRD009 S80 488
SXRD010 CX500, CX3-20 489
SXRD501, SXRD901 CX500, CX3-20 490

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Siemens Computers pmn and is the answer not in the manual?

Fujitsu Siemens Computers pmn Specifications

General IconGeneral
BrandFujitsu Siemens Computers
Modelpmn
CategorySoftware
LanguageEnglish