486 U41117-J-Z125-7-76
Message lines Explanation of console messages
SXRD001 NOTICE: raidd: 0:0:1 - disk state changed (Dead -> Write-Only)
Meaning
A rebuild is active for the physical disk of controller 0, channel 0, target ID 1.
SXRD001 NOTICE: raidd: 0:0:1 - disk state changed (Dead -> Online)
Meaning
A rebuild was successful for the physical disk of controller 0, channel 0, target ID 1. All the
associated logical disks are fully operational (redundant) again.
SXRD001 ALERT: raidd: c50d0 - state changed (Online -> Critical)
Meaning
The logical disk 0 on controller 0 no longer provides any redundancy. This indicates a
hardware problem with a physical disk belonging to the addressed logical disk.
Response
Notify maintenance staff.
SXRD001 ALERT: raidd: c50d0 - state changed (Critical -> Offline)
Meaning
A further physical disk belonging to the logical disk 0 on controller 0 has failed. The
addressed logical disk is no longer accessible.
Response
Notify maintenance staff.
SXRD001 NOTICE: raidd: c50d0 - state changed (Critical -> Online)
Meaning
The logical disk 0 on controller 0 has completed a rebuild and once again provides redun-
dancy.
Messages during the start phase
SXRD001 ALERT: raidd: 0:0:3 - disk state is Dead
Meaning
This message is only generated when the raidd is started at system boot. The physical disk
on controller 0, bus 0, target 3 was failed as the system booted. This indicates a hardware
problem with the addressed physical disk.
Response
Notify maintenance staff.
SXRD001 ALERT: raidd: 0:0:3 - disk state is Write-Only
Meaning
This message is only generated when the raidd is started at system boot. As the system
was started a rebuild was active for the physical disk on controller 0, bus 0, target 3.