Page #506 background imageLoading...
Page #506 background image
506 U41117-J-Z125-7-76
Message lines Explanation of console messages
SXSM049 sma#: Primergy Product Serial Number not available
ALERT
Meaning
The product serial number of the Primergy is not available. This can be caused by the
following:
a) The product serial number is not entered in the Primergy IdProm (e.g. after the ID chip
has been replaced).
b) The ID chip is defective.
c) The connection (cable/connector) to the IdProm is defective.
Response
Notify maintenance staff.
SXSM050 smasv: Server Management terminated (unrecoverable error or unsupported HW)
ALERT
Meaning
The Server Management has shut down. This can be caused by the following:
a) An unrecoverable error while the Server Management was running
b) An unrecoverable error while accessing the Primergy hardware/firmware
c) Primergy type not supported
Response
Notify maintenance staff.
SXSM051 sma#: Fan <Id>: Fan is working [again]
WARNING
Meaning
Fan <Id>, which was previously reported to be defective, is operating again.
Response
If error messages frequently occur for the fan in question: Notify maintenance staff.
SXSM052 sma#: CPU <Id> is not present
ALERT
Meaning
CPU <Id> has been removed or has failed.
Response
Notify maintenance staff.
SXSM053 sma#: CPU <Id> prefailure detection event
ALERT
Meaning
A large number of internal recoverable errors have occurred in CPU <Id>. This could result
in a CPU failure.