U41117-J-Z125-7-76 85
Operating and monitoring CentricStor Technical design
The figure below shows the components and the connections used for control and
monitoring (the Fibre Channel networking and the paths to the hosts are not shown):
Figure 30: GXCC components with X11 server as remote computer
In this example GXCC runs on a CentricStor computer. The data is made available by the
VLP InfoBroker. All GXCC output data is sent to the remote computer (X11 server) and
there displayed on the screen.
In the case of a low-speed data connection between CentricStor and the remote computer
the large data quantities to be transferred result in performance problems.
Consequently a configuration without X11 server provides a better solution:
Figure 31: Components of GXCC with a remote computer (not an X11 server)
GXCC
Remote computer
X11
server
GXCC
SCSI or FC interface
LAN or TCP/IP connection within processor
LAN
ICP
InfoBroker
SCSI components
IDP
InfoBroker
SNMP components
FC fabric
CentricStor
VLP
InfoBroker
GXCC
ouput data
GXCC
FC fabric
CentricStor
Remote computer
VLP
InfoBroker
GXCC
GXCC user data in ASCII
New data available?