17.4 Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component Notes
System board no TPM or expansion cards installed
1 CPU with CPU heat
sink
installed in CPU slot CPU 1
1 memory module installed in DIMM slot 1A
Common Operation
Panel (COP)
1 PSU installed in PSU bay PSU 1
Table 3: Minimum startup configuration - components
Cable Notes
Front panel cable
Power cable
Table 4: Minimum startup configuration - cables
"Shutting down the server" on page 48.
"Disconnecting the power cord" on page 49
.
Take the system down to its minimum startup configuration.
"Connecting the power cord" on page 62.
Connect a display to the server.
Switch on the server, see "Switching on the server" on page 66.