7.5.9 Replacing the 10x 2.5-inch HDD backplane
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Locating the defective server" on page 45.
▶
If applicable, "Removing the front cover with lock" on page
48.
▶
"Shutting down the server" on page 48.
▶
"Disconnecting the power cord" on page 49.
▶
"Getting access to the component" on page 52.
▶
Release all HDD/SSD modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD module" on page 143.
CAUTION
The HDD/SSD modules need not to be removed.
▶
If you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them
into their original bays.
▶
Release all dummy modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD dummy module" on page
140.
▶
If applicable, remove the internal RAID riser module, see "Removing the
internal RAID riser module (option)" on page
153.
Hard disk drive (HDD) / solid state disk (SSD)
158 Upgrade and Maintenance Manual RX2530 M6