Click on Reset Status.
Ensure that all pre-fail/fail status issues have been resolved in ServerV
iew
Operations Manager
.
Using the command line (Linux only)
Proceed as follows to reset the error counter of a specific CPU:
Log in as root.
Enter the command below, followed by [ENTER]:
<CPU#> parameters are "0" for CPU 1 and "1" for CPU 2.
For rack and floorstand servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number
, enter the following command:
/usr/sbin/eecdcp -c oc=E204
If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all CPUs:
Log in as root.
Basic software procedures
94 Upgrade and Maintenance Manual RX4770 M6