EasyManuals Logo

Fujitsu PRIMERGY RX4770 M6 User Manual

Fujitsu PRIMERGY RX4770 M6
468 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
â–¶
Click on Reset Status.
â–¶
Ensure that all pre-fail/fail status issues have been resolved in ServerV
iew
Operations Manager
.
Using the command line (Linux only)
Proceed as follows to reset the error counter of a specific CPU:
â–¶
Log in as root.
â–¶
Enter the command below, followed by [ENTER]:
<CPU#> parameters are "0" for CPU 1 and "1" for CPU 2.
For rack and floorstand servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number
, enter the following command:
/usr/sbin/eecdcp -c oc=E204
If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all CPUs:
â–¶
Log in as root.
Basic software procedures
94 Upgrade and Maintenance Manual RX4770 M6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX4770 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX4770 M6 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX4770 M6
CategoryServer
LanguageEnglish

Related product manuals