EasyManuals Logo

Fujitsu PRIMERGY RX4770 M6 User Manual

Fujitsu PRIMERGY RX4770 M6
468 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #269 background imageLoading...
Page #269 background image
"Switching on the server" on page 60
.
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the
message CPU has been changed.
This only indicates that the CPU configuration has been altered.
There is no technical problem.
Proceed as follows:
Restart your server.
As soon as the startup screen appears, press the [F2] function key
to enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Select the Exit menu.
Select Commit settings and Exit.
Verify that the Global Error indicator stops flashing.
If applicable, "Installing the front cover with lock" on page
61
.
"Resuming BitLocker functionality" on page 104.
11.4 Replacing a CPU or heat sink
For CPU1 or CPU2 on the bottom system board:
Field Replaceable Unit
(FRU)
Hardware: 20 minutes
Software: 5 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver (for cover 2)
T
orx 30 screw driver (for CPU heatsink)
For CPU 3 or CPU 4 on the top system board:
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Software: 5 minutes
Processor (CPU)
RX4770 M6 Upgrade and Maintenance Manual 269

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX4770 M6 and is the answer not in the manual?

Fujitsu PRIMERGY RX4770 M6 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX4770 M6
CategoryServer
LanguageEnglish

Related product manuals