ADVANCED FUNCTIONS AND OPERATIONS: Setting Tangential Emulation
6-50
S
ETTING OVERCUT
An overcut setting screen is displayed for the cutter-pen condition numbers for
which tangential emulation is enabled. The amount of overcut can be specified for
the start and end points. This function is particularly effective for aligning the start
and end pointswhen cutting thick materials such as rubber.
1 Press the function key F1 through F4 corresponding to the cutter-pen setting
area for which tangential emulation is enabled, and which requires an overcut
setting. Number 4 is used for the explanations in this section.
2Press the CONDITIONS key. A menu similar to the following appears
3Press the ENTER key.
4 To change the overcut amount for the start point, press the F3 key to move the
blinking cursor to that position. To change the overcut amount for the end
point, press the F4 key to move the blinking cursor to that position. Use the
(▲▼) POSITION keys to increase or lower the value at the cursor position in
the range from 0.0 to 0.9 (mm).
5Press the ENTER key to register your setting(s).
This setting is retained in the plotter’s memory even when the power is turned
off.
CONDITION 25
TANGENTIAL 4 10
READY 4
CB15U-K30x 0
SET 25
CONDITION 4 10
4
CB15U-K30x 0
OVERCUT
START=0.2mm
END=0.2mm
Overcut amount
Overcut amount
Cutting direction
Cutting
start point
Cutting end point