ADVANCED FUNCTIONS AND OPERATIONS: Setting the DISTANCE ADJUST Function
6-57
S
ETTING THE DISTANCE ADJUST PARAMETER
A distance adjust parameter setting screen is displayed for the cutter-pen
condition numbers for which DISTANCE ADJUST has been specified.
1 Press the function key F1 through F4 corresponding to the cutter-pen setting
area for which DISTANCE ADJUST has been specified. (Number 4 is used for
the explanations in this section.)
2Press the CONDITIONS key. The following menu appears.
3Press the ENTER key. (If tangential emulation has also been enabled for the
same condition number, the overcut setting screen is displayed. In this case
press the ENTER key once again.)
If you wish to adjust the distance in the X-axis direction, press the F2 key to
select X =. If you wish to adjust the distance in the Y-axis direction, press the
F3 key to select X =. Use the (▲▼) POSITION keys to increase or lower the
value at the cursor position in the range from -2.00 to +2.00 (%). To reset the
values to the default value (0.00%), press the F4 key (RESET).
4Press the ENTER key to register your setting(s).
CAUTION: If cutting or plotting is performed using condition settings for which different
DISTANCE ADJUST settings were specified, the cutting or plotting will not be
aligned. If you change the settings on the same drawings, make the same DIS-
TANCE ADJUST settings.
This setting is retained in the plotter’s memory even when the power is turned
off.
CONDITION 4 25
10
READY 4
CB15U-K30x 0
SET 25
CONDITION 4 10
4
CB15U-K30x 0
DISTANCE ADJUST
CONDITION4 L= 0.00%
W= 0.00%
RESET>