TEST MODES AND TROUBLESHOOTING: Error Messages in GP-GL Command Mode
9-11
9.7 Error Messages in GP-GL Command Mode
Symptom Cause Solution
ERROR 1
COMMAND ERROR
The plotter received an unrecognizable
command.
Noise was input to the plotter upon
execution of the software application.
Press the ENTER key.
The software configuration regarding the
output device has been changed.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.
ERROR 4
PARAMETER
OVERFLOW
A command was received containing
numeric parameters that exceed that
command's permissible range.
The software configuration regarding the
output device has been changed.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.
ERROR 5
I/O ERROR
An error occured in the receipt of data
within the interface.
The software command settings for
connecting changed,
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.