TEST MODES AND TROUBLESHOOTING: Error Messages in GP-GL Command Mode
9-11
9.7 Error Messages in GP-GL Command Mode
Symptom Cause Solution
ERROR 1
COMMAND ERROR
The plotter received an unrecognizable
command.
• Noise was input to the plotter upon
execution of the software application.
Press the ENTER key.
• The software configuration regarding the
output device has been changed.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
• The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.
ERROR 4
PARAMETER
OVERFLOW
A command was received containing
numeric parameters that exceed that
command's permissible range.
• The software configuration regarding the
output device has been changed.
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
• The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.
ERROR 5
I/O ERROR
An error occured in the receipt of data
within the interface.
• The software command settings for
connecting changed,
Configure the software to drive your
plotter.
Ensure that the software's interface
conditions are correctly set.
• The plotter's interface conditions have
been changed.
Ensure that the plotter's interface
conditions are set to match those of the
software.