TEST MODES AND TROUBLESHOOTING: Error Messages in HP-GL Command Mode
9-13
ERROR 12
INVALID BYTE IN I/O
CONTROL
A device control command
containing an invalid byte
was received.
Check the device control
commands in your
program.
ERROR 13
OUT OF RANGE I/O
PARAMETERS
A parameter outside of the
permissible range was
specified.
Check the parameter
ranges in your program.
ERROR 14
TOO MANY I/O
PARAMETERS
Too many parameters
were received.
Check the number of
command parameters in
your program.
ERROR 15
ERROR IN I/O
TRANSMISSION
During data transfer, a
framing error, parity error
or overrun error occurred.
Check the settings of the
interface conditions.
ERROR 16
I/O BUFFER
OVERFLOW
The I/O buffer received
data at a faster pace than
it could process indicating
that handshake was not
successful.
Check the settings of the
handshake mode and
other interface conditions.