upper-value: Upper temperature limit in Celsius degrees. The value ranges from 20 to
90.
The upper-value argument must be larger than the lower-value argument.
Description
Use the temperature-limit command to set the temperature alarm threshold on a
board.
Use the undo temperature-limit command to restore the temperature alarm threshold
to the default.
By default, the temperature alarm threshold depends on your AC model.
NOTE:
The upper-value argument must be bigger than the lower-level argument.
Support for this command depends on your AC model.
Examples
Set the lower temperature limit on board 1 to 10 Celsius degrees and the upper
temperature limit to 75 Celsius degrees.
<Sysname> system-view
[Sysname] temperature-limit 1 10 75
Setting temperature limit succeeded.
time
Syntax
time timeID at time1 date command command
time timeID { one-off | repeating } at time1 [ month-date month-day | week-day
week-daylist ] command command
time timeID { one-off | repeating } delay time2 command command
undo time timeID
View
Job view
Default Level
3: Manage level
Parameters
timeID: Time index, an integer ranging from 1 to 10.